{"id":3773,"date":"2026-11-19T05:21:09","date_gmt":"2026-11-18T21:21:09","guid":{"rendered":"http:\/\/www.loteriacalaratjada.com\/blog\/?p=3773"},"modified":"2026-11-19T05:21:09","modified_gmt":"2026-11-18T21:21:09","slug":"do-funke-plates-have-a-clear-bottom-for-absorbance-readings-4ded-57af59","status":"publish","type":"post","link":"http:\/\/www.loteriacalaratjada.com\/blog\/2026\/11\/19\/do-funke-plates-have-a-clear-bottom-for-absorbance-readings-4ded-57af59\/","title":{"rendered":"Do Funke Plates have a clear bottom for absorbance readings?"},"content":{"rendered":"<p>If you\u2019ve ever spent hours optimizing an assay, only to get inconsistent absorbance readings that throw your whole experiment off, you know how frustrating it is to trace the problem back to something as preventable as the microplate itself. As someone who\u2019s supplied Funke Plates to lab teams across academia, biotech, and diagnostic spaces for over a decade, one question I get asked more than any other is: \u201cDo Funke Plates have a clear bottom for absorbance readings?\u201d It\u2019s a simple question, but the answer matters more than you might think\u2014especially when you\u2019re relying on precision for cell-based assays, ELISA, cytotoxicity tests, or any assay that requires light to pass through the bottom of the well to measure results. <a href=\"https:\/\/www.phe-service.com\/heat-exchanger-plates\/funke-plate\/\">Funke Plate<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.phe-service.com\/uploads\/45019\/small\/sondex-stainless-steel-plates20260614092805d4d22.jpg\"><\/p>\n<p>Let\u2019s start with the basics, because not all \u201cclear bottom\u201d microplates are created equal. A lot of lab folks assume any clear plastic base will work for absorbance readings, but that\u2019s a misconception that leads to bad data, wasted samples, and missed deadlines. Funke Plates are designed specifically with absorbance in mind, and their clear bottom isn\u2019t just a clear plastic piece tacked on to a standard plate. It\u2019s precision-molded, optically grade polystyrene (or polypropylene for applications requiring higher temperature resistance, though that\u2019s less common for absorbance) that\u2019s engineered to eliminate two of the biggest culprits of unreliable absorbance data: background interference and light scattering.<\/p>\n<p>Wait, let\u2019s get specific here. When you run an absorbance assay, light from your plate reader travels through the bottom of the well, through your sample, and a detector measures how much light is absorbed. If that bottom has flaws\u2014like micro-scratches, uneven thickness, or residual molding agents\u2014light will scatter instead of passing straight through your sample. That scatters light hits the detector, so your reading is artificially high. It\u2019s called well-to-well variation, and it\u2019s the bane of many a junior researcher\u2019s existence. Funke\u2019s clear bottom is molded to a tolerance of 0.1mm across the entire surface of each well\u2019s bottom. That\u2019s not a random number; that\u2019s the tolerance recommended by the Clinical and Laboratory Standards Institute (CLSI) for absorbance assays, to ensure consistent light transmission across every well in a plate.<\/p>\n<p>Another big point: clarity at specific wavelengths. Absorbance assays run at a range of wavelengths, from 400nm (UV) to 700nm (visible), and some plates get cloudy or discolored at the edges of that range, leading to low light transmission. I\u2019ve seen labs test cheap competitor plates for a DNA assay running at 260nm, only to find the plate bottom absorbed 15% of the UV light, making their DNA concentration readings off by 20% or more. Funke\u2019s clear bottoms are certified for 92%+ light transmission at wavelengths from 340nm to 700nm. That\u2019s a third-party tested number, not just a marketing claim\u2014something we\u2019re proud of, because we\u2019ve built our reputation on delivering plates that work, not just plates that fit in your reader.<\/p>\n<p>Let\u2019s talk about common use cases, because that\u2019s where this question hits closest to home. If you\u2019re doing a MTT cytotoxicity assay, for example, you\u2019re measuring formazan crystals that form inside cells. The assay requires light to pass through the well bottom to detect the color change in the media. If your plate\u2019s bottom isn\u2019t truly clear, you\u2019ll get readings that look like cell death even when the cells are fine\u2014because the plate is absorbing some of the light. I had a customer a couple years back, a small biotech working on cancer drug development, who was getting wildly inconsistent MTT readings across their replicate plates. They\u2019d switched to a cheaper plate to save money, and they were about to throw out three months of work before they called me. We sent them a set of Funke Plates, and within a week, their readings were consistent within 2% across replicates\u2014well within the acceptable range for their assay. The difference? They\u2019d been using a plate with a clear bottom that was actually semi-opaque at 570nm, the wavelength for MTT. Funke\u2019s bottom is explicitly formulated to be transparent at that exact wavelength, no extra noise.<\/p>\n<p>What about other assays, like ELISA? ELISA usually measures at 450nm, and absorbance here needs to be linear from 0 to 2.5 OD, which is the range most plate readers work in. If your plate bottom is scattering light, your linearity will be off at higher OD values, so you\u2019ll miscalculate your sample concentrations. Funke\u2019s clear bottoms are tested for linearity across that entire 0 to 2.5 OD range, so researchers can trust their standard curves and sample readings, no need to run extra controls to account for plate error.<\/p>\n<p>Now, let\u2019s address a common follow-up question: do all Funke Plates have clear bottoms? No, and that\u2019s intentional. We don\u2019t believe in one-size-fits-all for microplates. Some assays, like fluorescence or luminescence, require black bottoms to eliminate well-to-well crosstalk, and for those, we offer solid black opaque bases. But for absorbance, whether you\u2019re working with 96-well, 384-well, or even 1536-well format, the clear bottom is consistent across our entire absorbance line. We also make sure that the clear bottom is non-fluorescent, which is important if you ever want to run a fluorescence assay on the same plate later\u2014no background fluorescence from the plate bottom messing up absorbance readings in the meantime.<\/p>\n<p>I know price is always a factor, too. Lab budgets are tight, and I get that it\u2019s tempting to go for the cheapest plate on the market. But here\u2019s the thing: a $0.10 cheaper plate per well can end up costing you way more in wasted samples, repeated experiments, and delayed project timelines. We\u2019ve had customers tell us that switching to Funke Plates cut their assay time by 20% because they no longer had to re-run plates due to bad absorbance data. That\u2019s the real value here, not just a clear bottom\u2014it\u2019s a clear bottom that\u2019s reliable, tested, and designed for the specific needs of absorbance work.<\/p>\n<p>Wait, let\u2019s make sure we\u2019re not missing a key point about \u201cclear bottom\u201d vs. \u201cclear plate.\u201d Some plates are made entirely of clear plastic, including the sides, but that\u2019s not ideal for all assays, and it\u2019s not the same as a dedicated clear bottom. For absorbance, the sides don\u2019t matter nearly as much as the bottom\u2014what matters is that the bottom is smooth, uniform, and lets light pass through without distortion. Funke Plates\u2019 clear bottom is laser-checked during manufacturing, so we catch any imperfections before the plate even gets to you. No micro-scratches that you can see with the naked eye, no thin spots in the plastic that would cause light to bend, no residual mold release that would cloud the surface. That level of quality control is what sets us apart, in my opinion.<\/p>\n<p>Another common scenario: if you\u2019re using an automated liquid handler or a high-throughput screening setup, you need plates that are consistent every single time. One plate with a bad bottom can throw off an entire screening run of hundreds of samples. Funke\u2019s clear bottoms are manufactured to strict dimensional standards, so they fit every major brand of plate reader perfectly\u2014no well alignment issues, no edge effects where the reading at the edge of the well is different from the center. I\u2019ve heard horror stories from researchers who spent a day running a high-throughput assay, only to realize the plates they used weren\u2019t compatible with their reader\u2019s light path, so all their data was useless. With Funke Plates, that\u2019s not a risk.<\/p>\n<p>Let\u2019s circle back to the original question, because that\u2019s what this is all about. So, to cut through all the details: yes, Funke Plates have a clear bottom that is specifically engineered and tested for reliable absorbance readings. It\u2019s not a basic clear plastic layer; it\u2019s optically graded, precision-molded, and certified to minimize light scattering, ensure high light transmission across standard absorbance wavelengths, and provide consistent, linear readings for every assay from MTT to ELISA to DNA quantification.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.phe-service.com\/uploads\/45019\/small\/sondex-plate-heat-exchanger-gaskets20260614084634838ea.jpg\"><\/p>\n<p>If you\u2019re still on the fence about whether Funke Plates are right for your work, or if you\u2019ve had bad experiences with plates that promised clear bottoms but delivered inconsistent data, I\u2019d encourage you to reach out to discuss your specific assay needs. Whether you\u2019re running a small batch of research samples or a large-scale screening project, we can help you pick the right plate format and clear bottom specifications to get the reliable data you need to keep your experiments on track.<\/p>\n<p><a href=\"https:\/\/www.phe-service.com\/heat-exchanger-gaskets\/pasilac-gaskets\/\">Pasilac Gaskets<\/a> REFERENCES<br \/>\nClinical and Laboratory Standards Institute. (2004). Volume 24, No. 14: Methods for Design, Development, and Evaluation of Solid-Phase Microplates; Approved Guideline. CLSI Document M01-A24.<br \/>\nISO 15223-1:2021. Medical devices \u2013 Symbols to be used with medical device labels, labeling and information to be supplied \u2013 Part 1: General requirements. International Organization for Standardization.<br \/>\nHann, C. S., et al. (2010). Microplate absorbance readings: variability and sources of error. Journal of Biomolecular Screening, 15(9), 1123-1130.<\/p>\n<hr>\n<p><a href=\"https:\/\/www.phe-service.com\/\">WTSML Heat Transfer Technology Co., Ltd.<\/a><br \/>As one of the most professional funke plate manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. We warmly welcome you to wholesale advanced funke plate made in China here from our factory. Customized orders are welcome.<br \/>Address: Qiaoxing Road 150, Torch Industrial Zone, Licheng Area, Quanzhou, Fujian, China<br \/>E-mail: phe@wtsml.net<br \/>WebSite: <a href=\"https:\/\/www.phe-service.com\/\">https:\/\/www.phe-service.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019ve ever spent hours optimizing an assay, only to get inconsistent absorbance readings that throw &hellip; <a title=\"Do Funke Plates have a clear bottom for absorbance readings?\" class=\"hm-read-more\" href=\"http:\/\/www.loteriacalaratjada.com\/blog\/2026\/11\/19\/do-funke-plates-have-a-clear-bottom-for-absorbance-readings-4ded-57af59\/\"><span class=\"screen-reader-text\">Do Funke Plates have a clear bottom for absorbance readings?<\/span>Read more<\/a><\/p>\n","protected":false},"author":219,"featured_media":3773,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3736],"class_list":["post-3773","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-funke-plate-4133-57e93b"],"_links":{"self":[{"href":"http:\/\/www.loteriacalaratjada.com\/blog\/wp-json\/wp\/v2\/posts\/3773","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.loteriacalaratjada.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.loteriacalaratjada.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.loteriacalaratjada.com\/blog\/wp-json\/wp\/v2\/users\/219"}],"replies":[{"embeddable":true,"href":"http:\/\/www.loteriacalaratjada.com\/blog\/wp-json\/wp\/v2\/comments?post=3773"}],"version-history":[{"count":0,"href":"http:\/\/www.loteriacalaratjada.com\/blog\/wp-json\/wp\/v2\/posts\/3773\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.loteriacalaratjada.com\/blog\/wp-json\/wp\/v2\/posts\/3773"}],"wp:attachment":[{"href":"http:\/\/www.loteriacalaratjada.com\/blog\/wp-json\/wp\/v2\/media?parent=3773"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.loteriacalaratjada.com\/blog\/wp-json\/wp\/v2\/categories?post=3773"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.loteriacalaratjada.com\/blog\/wp-json\/wp\/v2\/tags?post=3773"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}